655 kW Steam Turbine with Generator. System includes, Dresser-Rand Coppus RLHA 24 Turbine, Marathon Synchronous Generator, and Lufkin Speed Reducing Gearbox. Year 2013. Turbine Generator Skid: A common steel base is provided for the turbine, speed reducing gear and generator. The turbine and gear are coupled with a Lovejoy flexible stainless steel disc spacer type coupling, dynamically balanced to a maximum 2.5 mm/sec of vibration and meeting ISO G2.5. The generator and gear are coupled with a Lovejoy gear-type coupling with a 1.5 service factor. Coupling guards are installed over both couplings. Skid piping includes all piping necessary to collect condensate drains, steam leak offs and instrument air to single field connection point. Manual globe valves are installed in condensate drain lines for startup condensate removal. Skid wiring includes all conductors and conduit necessary to consolidate terminations for all skid instrumentation and control devices in a common terminal box.