Heat Recovery (HRSG)

Heat Recovery HRSG Boilers for Sale.

250000 LB/HR; 900 PSI; Deltak HRSG designed for use with an LM6000 Gas Turbine

126041
250000 LB/HR; 900 PSI; Deltak HRSG designed for use with an LM6000 gas turbine generator unused surplus new in 2001. Includes Duct Burners. This heat recovery boiler produces both Low and High pressure super-heated steam. As originally delivered the Deltak HRSG included: Duct Burner – Natural Gas Fired; High and Low Pressure Boiler SuperHeater and Economizer; Complete Feedwater System; Valves; Support Structural Steel; Fuel Skid; Platforms Walk ways and Stack.

46500 Lbs/Hr. Deltak HRSG 21 Tons/Hr steam flow 13.79 Bar (200 PSI) Operating Pressure

126219
46500 Lbs/Hr. Deltak HRSG 21 Tons/Hr steam flow 13.79 Bar (200 PSI) Operating Pressure 17.24 Bar (250 PSI) Design Pressure HRSG YOM 1996 in very good condition. HRSG includes the following equipment Diverter (bypass) Valve Economizer Boiler (Evaporator) Bypass Stack All transition Ducts Stack. Also can include a DA Tank and Feedwater Pumps. All Available Documentation Included.

183600 Lbs/Hr Rentech HRSG Steam Boiler System; New/Unused Surplus; with Supplmental Burner

126803
183600 Lbs/Hr Rentech HRSG Steam Boiler System New/Unused Surplus Equipment with 225 PSIG Design Pressure Year 2016. Comes with Supplemental Duct Burner Rated for 119.6 MMBtu/hr Fuel Natural Gas. Total Airflow Volume Capacity is rated for 367455 Lbs/Hr. This system was designed for operation with a Solar Titan 130 Gas Turbine. Under normal operating condition with a Titan 130 this HRSG will output 60000 Lbs/Hr. Steam without use of the Supplemental Duct Burner. Complete System Includes: Inlet Duct Duct Burner Burner controls and fuel skid Evaporator Outlet Duct Economizer Stack Ladders/Platforms Standard Boiler Instrumentation and Valves Feedwater Trim Deaerator / Feedwater Pumps all available engineering and documentation. Built in 2016.

1015 Ton Absorption Chillers, Qty (2), Series 5G

467062
Two (2) Thermax, Series 5G, single effect hot water driven vapor absorption chillers engineered to each produce 1015 tons of chilled water at 42 °F of using 17,374 MBH of recovered heat from a waste heat hot water boiler. Thermax Absorption Chillers, New 2012. The chillers will be capable of operating in-series as well as in parallel mode.

Rentech Waste Heat Recovery Boiler

467063
WHRU – Rentech Hot Water Boiler rated for 690,000 lbs. water an hour (1,377 GPM). A combustion exhaust stream is used to heat approximately 690,000 pounds of water per hour from 170 °F to 225 °F at an ambient condition of 55 °F. Designed for use with a Solar Turbines, Taurus 70 Gas Turbine Generator.